What Should Be Done to Reduce Refrigerant Loss From a Purge Unit on a r-123 Chiller?: Expert Tips and Best Practices

Cut Refrigerant Costs. Comply with EPA. Extend Chiller Life.

Heidi home improvement
what should be done to reduce refrigerant loss from a purge unit on a r-123 chiller?

Refrigerant loss in low-pressure chillers, particularly those using R-123, is a common issue that can lead to increased costs, reduced efficiency, and potential environmental compliance violations. One of the most overlooked causes of refrigerant emissions is the purge unit, which is responsible for removing non-condensable gases from the system.

In this comprehensive guide, we’ll explain how to reduce refrigerant loss from a purge unit on an R-123 chiller using proven strategies, real-world examples, and actionable steps. Whether you’re a facility manager, HVAC technician, or compliance officer, these tips will help you operate more efficiently and sustainably.

Detect and Repair Air Leaks

R-123 chillers operate under vacuum, which makes them susceptible to air infiltration. This air must be removed by the purge unit, but excessive air entry increases the frequency of purge cycles, leading to greater refrigerant loss.

Recommended Actions:

  • Conduct regular visual inspections for signs of oil or pressure anomalies.
  • Use electronic or ultrasonic leak detectors to pinpoint small leaks.
  • Perform soap bubble tests on valves, flanges, and joints.

Example:

A healthcare facility using a Trane R-123 chiller discovered a small leak at the purge suction line, which increased purge operation frequency to every hour. After repairing the gasket, the frequency dropped to once every 12 hours, saving over 20 pounds of refrigerant annually.

Optimize Purge Unit Discharge

Traditional purge units often discharge a mixture of non-condensables and refrigerant into the atmosphere. This not only contributes to refrigerant loss but also violates environmental regulations.

Recommended Actions:

  • Ensure the purge unit discharge line is sealed and properly routed.
  • Install a recovery canister or refrigerant return line.
  • Upgrade to a closed-loop or high-efficiency purge unit to eliminate venting losses.

Maintain and Calibrate the Purge Unit

Routine maintenance ensures the purge unit functions correctly and efficiently.

Maintenance Tips:

  • Clean purge filters, sensors, and valves regularly.
  • Inspect and replace worn gaskets.
  • Check float valve operation and oil separation components.

Monitoring the purge cycle run-time helps detect problems early. Increased frequency usually signals an air leak or system contamination.

Minimize Non-Condensables in the System

Non-condensable gases reduce system efficiency and increase the workload on the purge unit.

Best Practices:

  • Replace system filters on a routine schedule.
  • Periodically flush the system with dry nitrogen to eliminate moisture and air.
  • Clean heat exchanger tubes to improve heat transfer and reduce air entry points.

Use Proper Refrigerant Recovery and Charging Methods

Improper refrigerant handling can contribute to unnecessary loss during servicing or shutdown.

Best Practices:

  • Always use EPA-certified recovery machines.
  • Store refrigerant in approved, clearly labeled cylinders.
  • Charge the system with the correct amount of refrigerant per manufacturer specifications.

Reference: EPA Refrigerant Management – Section 608

Monitor and Log Performance Data

Implementing a monitoring system helps track purge unit activity and detect potential leaks. For accurate compliance reporting, it’s critical to understand how to determine a chiller’s normal charge.

What Is the Best Method to Determine a Chiller’s Normal Charge for Leak Rate Calculations?

What to Track:

  • Purge unit cycle frequency and run time
  • Refrigerant usage trends and inventory
  • Daily temperature and pressure readings
  • Leak inspection and repair logs

A digital chiller logbook or computerized maintenance management system (CMMS) can simplify this process.

Bonus: Upgrade to High-Efficiency Purge Units

Modern purge systems are designed to recover refrigerant, operate more efficiently, and provide diagnostics that reduce downtime.

Example: After installing a Trane EarthWise purge unit, a commercial office building reduced refrigerant emissions by over 90% and minimized service intervals.

Frequently Asked Questions

Can refrigerant be legally vented during purging?

No. Under EPA Section 608, it is illegal to knowingly release refrigerant to the atmosphere. All purge discharge must be recovered or rerouted.

How much refrigerant can be lost through an inefficient purge unit?

Depending on purge frequency and leak severity, a system can lose between 5 and 50 pounds of refrigerant annually.

Is refrigerant recovery required during service or decommissioning?

Yes. Proper refrigerant recovery is mandatory and must follow EPA guidelines using certified equipment.

Conclusion: How to Reduce Refrigerant Loss from a Purge Unit on an R-123 Chiller?

Reducing refrigerant loss from a purge unit on an R-123 chiller is critical for cost savings, system longevity, and environmental compliance. By implementing leak detection, optimizing purge system discharge, maintaining purge components, and properly managing refrigerant, facilities can dramatically lower emissions and operating expenses.

These best practices not only protect your bottom line but also demonstrate a commitment to sustainability and regulatory responsibility.

Want a downloadable maintenance checklist or SOP for your facility? Just ask!

Share This Article
Heidi Home Improvement is a home expert at Home Revista, specializing in home services, safety, efficiency, outdoor living, storage, cleaning, and real estate. Passionate about helping homeowners create beautiful, functional, and sustainable spaces, Heidi provides expert advice, inspiring ideas, and practical solutions to make every home better.
1 Comment